Minggu, 20 November 2011

COMPARISONS BETWEEN THE MODALITIES Contrast Agents


Contrast agents

CT
·  Iodine used iv
·  Z= 53
·  K edge 33 keV-attenuation high
·  Photo electric absorption greater than in tissue or bone due to high atomic number of I
·  Can get renal failure and allergic reactions

US
·  encapsulated micro bubbles
·  used in perfusion and vascular imaging
·  Large diff in acoustic impedance between bubbles and fluids /tissue
·  Small bubbles =point source =they are smaller than wave =reflections in all directions
·  Bubbles compressible -produces shifts in returning frequencies (harmonics)
·  Reflections of bubbles travel only 1/2 the distance the US beam has to travel

MRI
·  Gadolinium DTPA
·  paramagnetic contrast agent
·  reduces T1 significantly --  strong signal  --  and T2 slightly  --  weak signal
·  Can get nephrogenic systemic fibrosis

Tidak ada komentar: